1 AXIS AZIMUTHAL TRACKER
The 1 axis azimuthal (seasonal) tracker, received the “PV Application Award 2009” in Hamburg, Germany, during the EUPV trade show, Recognizing MECASOLAR’s commitement into new technological developements as per the needs and the demands of the pv market.
ADAPTABLE AND FLEXIBLE SOLUTION
The design of the H frame support structure provides the MECASOLAR tracker with substantial flexibility regarding the installation of modules compared to other manufacturers. The system can host up to 19Kw*
MANUALLY ADJUSTABLE POLAR TILT
The plots occupied by the MS-1E TRACKER are very similar those occupied by the traditional NONseasonal 1-axis solar tracker, resulting in a greater return on investment.
FOUNDATION
Foundation on surface footing – 10 cubic yards (7.5 m3) – not requiring any excavation. It is necessary, however, to clear the terrain by removing the top layer of vegetation and levelling the ground.
INDEPENDENT CONTROL
Each MECASOLAR solar tracker integrates an independent PLC controller, working to monitor solar movements, in order to handle the prevailing weather conditions and perform remote operations.
MINIMAL CONSUPTION, NO WELDING ON SITE AND SIMPLY INSTALLATON.
The mecasolar motors consume less energy per year (40 kWh/year), resulting in minimal consumption. The entire tracker can be assembled with fastening devices, therefore on-site weldings are NOT required, reducing workforce cost and mounting time. The ergonomy of the design ensures minimum equipment and installation effort.
Tracker axsis | 1-AXIS: Azimuth (vertical) |
---|---|
Module maximum surface | 1,140 square feet (106m) |
Grillsizes | 43.5 feet x 26 feet (13.3 m x 8 m) |
Maximum Photovoltaic power | 15.36 kWp (depending on the efficiency of the modules) |
Azimuthdrive | By gear motor and cogged crown wheel |
Azimuth rotation angle | Vertical axis: -120° to + 120° |
Tilt Actuator | Manual micrometric screw |
Motor consumption | 40 kWh / year |
Motor operating voltage | 380 V Three-phase |
Structure | Hot dipped galvanized steel structure |
Structure design | Base structure on cogged crown wheel |
Weight without modules, and without foundation | 4,630 lb (2,100kg) |
Electrical cabinets and PLC Protection | Metal, weathertight, fully wired IO55. Includes PLC, wired to motor and protection |
Electrical supply cabinet | Metal, weathertight, fully wired IP66. Includes AC overvoltage protection, PLAs and differential (only for MS-1E TRACKER 15+) |
Tracking technology | Independent Astronomical programming of PLC |
Monitoring | On-site, Etherent, Intermet (OPTIONAL) |
modules to be installed | Any type of PV modules Module holder profile not required |
maximum weiight of modules | 3,307 lb (1,500 kg) |
Wind protection system | Weather vane position at speeds greater then 60 km/h |
Foundation | Circular suface footimg, 13 cubic yards (10m) concreate with mesh. Optional anchor bolts, direct bolt anchoring |
Standard Compliant with | EUROCODE 0 EUROCODE 1 EUROCODE 3 CE |
maintenance | Annual revision of electrical and mechanical parts to maintain the lifetime warranty |